Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Physiol Rep ; 6(8): e13668, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29696811

RESUMO

Abdominal aortic aneurysms are pathological dilations that can suddenly rupture, causing more than 15,000 deaths in the U.S. annually. Current treatment focuses on observation until an aneurysm's size warrants surgical intervention. Thus, there is a need for therapeutic intervention to inhibit growth of smaller aneurysms. An experimental aneurysm model that infuses angiotensin II into apolipoprotein E-deficient mice is widely used to investigate underlying pathological mechanisms and potential therapeutics, but this model has two caveats: (1) aneurysms do not always form, and (2) aneurysm severity and growth is inconsistent among animals. Here we use high-frequency ultrasound to collect data from angiotensin II-induced aneurysms to develop prediction models of both aneurysm formation and growth. Baseline measurements of aortic diameter, volume/length, and strain were used with animal mass and age in a quadratic discriminant analysis and logistic regression to build two statistical models to predict disease status. Longitudinal ultrasound data were also acquired from mice with aneurysms to quantify aneurysm diameter, circumferential strain, blood flow velocity, aneurysm volume/length, and thrombus and open-false lumen volumes over 28 days. Measurements taken at aneurysm diagnosis were used with branching artery information to produce a multiple linear regression model to predict final aneurysm volume/length. All three statistical models could be useful in future aneurysm therapeutic studies to better delineate the effects of preventative and suppressive treatments from normal variations in the angiotensin II aneurysm model.


Assuntos
Angiotensina II , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/induzido quimicamente , Animais , Aneurisma da Aorta Abdominal/induzido quimicamente , Apolipoproteínas E/genética , Modelos Animais de Doenças , Progressão da Doença , Masculino , Camundongos , Ultrassonografia
2.
J Biomech Eng ; 140(8)2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29570754

RESUMO

Recent applications of computational fluid dynamics (CFD) applied to the cardiovascular system have demonstrated its power in investigating the impact of hemodynamics on disease initiation, progression, and treatment outcomes. Flow metrics such as pressure distributions, wall shear stresses (WSS), and blood velocity profiles can be quantified to provide insight into observed pathologies, assist with surgical planning, or even predict disease progression. While numerous studies have performed simulations on clinical human patient data, it often lacks prediagnosis information and can be subject to large intersubject variability, limiting the generalizability of findings. Thus, animal models are often used to identify and manipulate specific factors contributing to vascular disease because they provide a more controlled environment. In this review, we explore the use of CFD in animal models in recent studies to investigate the initiating mechanisms, progression, and intervention effects of various vascular diseases. The first section provides a brief overview of the CFD theory and tools that are commonly used to study blood flow. The following sections are separated by anatomical region, with the abdominal, thoracic, and cerebral areas specifically highlighted. We discuss the associated benefits and obstacles to performing CFD modeling in each location. Finally, we highlight animal CFD studies focusing on common surgical treatments, including arteriovenous fistulas (AVF) and pulmonary artery grafts. The studies included in this review demonstrate the value of combining CFD with animal imaging and should encourage further research to optimize and expand upon these techniques for the study of vascular disease.


Assuntos
Simulação por Computador , Hidrodinâmica , Doenças Vasculares/fisiopatologia , Animais , Modelos Animais de Doenças , Hemodinâmica
3.
J Control Release ; 249: 53-62, 2017 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-28126527

RESUMO

Abdominal aortic aneurysms (AAAs) represent a potentially life-threatening condition that predominantly affects the infrarenal aorta. Several preclinical murine models that mimic the human condition have been developed and are now widely used to investigate AAA pathogenesis. Cell- or pharmaceutical-based therapeutics designed to prevent AAA expansion are currently being evaluated with these animal models, but more minimally invasive strategies for delivery could improve their clinical translation. The purpose of this study was to investigate the use of self-assembling type I collagen oligomers as an injectable therapeutic delivery vehicle in mice. Here we show the success and reliability of a para-aortic, ultrasound-guided technique for injecting quickly-polymerizing collagen oligomer solutions into mice to form a collagen-fibril matrix at body temperature. A commonly used infrarenal mouse AAA model was used to determine the target location of these collagen injections. Ultrasound-guided, closed-abdominal injections supported consistent delivery of collagen to the area surrounding the infrarenal abdominal aorta halfway between the right renal artery and aortic trifurcation into the iliac and tail arteries. This minimally invasive approach yielded outcomes similar to open-abdominal injections into the same region. Histological analysis on tissue removed on day 14 post-operatively showed minimal in vivo degradation of the self-assembled fibrillar collagen and the majority of implants experienced minimal inflammation and cell invasion, further confirming this material's potential as a method for delivering therapeutics. Finally, we showed that the typical length and position of this infrarenal AAA model was statistically similar to the length and targeted location of the injected collagen, increasing its feasibility as a localized therapeutic delivery vehicle. Future preclinical and clinical studies are needed to determine if specific therapeutics incorporated into the self-assembling type I collagen matrix described here can be delivered near the aorta and locally limit AAA expansion.


Assuntos
Aorta Abdominal/efeitos dos fármacos , Aneurisma da Aorta Abdominal/tratamento farmacológico , Colágeno Tipo I/administração & dosagem , Sistemas de Liberação de Medicamentos/instrumentação , Animais , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/patologia , Colágeno Tipo I/farmacocinética , Colágeno Tipo I/ultraestrutura , Desenho de Equipamento , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Ultrassonografia/instrumentação
4.
J Vis Exp ; (115)2016 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-27684327

RESUMO

A traditional vaporizer depends on flowing gas and atmospheric pressure for passive anesthetic vaporization. Newly developed direct injection vaporizers utilize a syringe pump to directly administer volatile anesthetics into a gas stream. Unlike a traditional vaporizer, it can be used at very low flow rates, making it ideal for use on mice and rats. The equipment's capability to use low flow rates could result in a substantial cost savings due to the reduced need for anesthetic agents, compressed gas, and charcoal scavenging filters(1). A lower flow rate means less waste of anesthetic gas and likely reduces the risk of anesthetic exposure to laboratory personnel. Thus, the high levels of precision and safety associated with direct injection vaporizers, along with a reduced need for anesthetic agents, compressed gas, and charcoal filters are beneficial for research requiring small animal anesthesia. The goal of this protocol is to demonstrate the use of a syringe-driven direct injection vaporizer as part of a digital, low-flow anesthesia system. The direct injection vaporizer is capable of accurately delivering anesthesia at very low flow rates compared to a traditional vaporizer, making it a promising alternative for controlled gas anesthetic delivery to rodents.


Assuntos
Anestesia/veterinária , Anestésicos Inalatórios , Anestesia/métodos , Animais , Camundongos , Ratos , Volatilização
5.
J Am Assoc Lab Anim Sci ; 54(6): 756-62, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26632785

RESUMO

Recent efforts have focused on mitigating anesthetic gas emissions during laboratory animal experiments. A recently developed, digitally controlled, integrated digital vaporizer (IDV) using a syringe pump has been designed to use and administer anesthetic gas to mice and rats more efficiently. The entire IDV system can be placed on a laboratory bench, requires fewer charcoal filters to act as passive scavengers when used at a low gas flow rate, and does not need compressed gas to operate, a requirement for traditional passive systems. The objective of this study was to compare isoflurane usage between a traditional vaporizer (TdV) and an IDV system at both the same settings and those recommended by the manufacturer. We used 10 C57BL/6 male mice and administered isoflurane through either nose cones or tracheal tubes connected to a pulsatile ventilator. The results showed that isoflurane usage is highly dependent on the flow rate of the carrier gas, but the IDV system was more precise and handled low flow rates (150 mL/min) better than did the TdV system. We observed only slight differences in heart rate, respiration rate, core body temperature, time to loss of the righting reflex, and recovery time between group averages for both systems when set to manufacturer-recommended settings. Although observed decreased levels of waste anesthetic gas at low flow rates are expected from the IDV system, further work is needed to assess environmental anesthetic gas levels and exposure to laboratory personnel.


Assuntos
Anestesia por Inalação/veterinária , Nebulizadores e Vaporizadores/veterinária , Anestesia por Inalação/instrumentação , Animais , Isoflurano/administração & dosagem , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Organismos Livres de Patógenos Específicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...